VN Compact Electromagnetic Flow Sensor_cảm biến đo lưu lượng Aichi Tokei Denki Vietnam
Xuất sứ: Nhật Bản
Nhà cung cấp: Pitesco
Hãng sản xuất: Aichi Tokei Denki
VNCompact Electromagnetic Flow Sensor
Features
This flow sensor is a compact version of our electromagnetic flow meters that has been designed to be easily built into equipment. It also has realized cost saving. It provides stable measurement and repeatability.
* We are happy to provide sample or evaluation products for customers who need to build the sensors into their equipments.
・Compact design, no straight piping is required for either side of the piping! Greater freedom in installation locations.
・Equipped with two outputs, this sensor broadens the choice of output, such as flow rate, switch judgment and self-diagnosis.
・Having no moving parts makes free of damage resulting from foreign substances.
Standard Specifications
Model | VN05 | VN10 | VN20 | ||
---|---|---|---|---|---|
Accuracy Guaranteed Flow Rate Range (Minimum flow rate – maximum flow rate) |
0.05 – 1 L/min | 0.5 – 10 L/min | 3.0 – 60 L/min | ||
Maximum operating flow | 3 L/min | 25 L/min | 100 L/min | ||
Low flow cut-off | 0.025 L/min | 0.25 L/min | 1.5 L/min | ||
Accuracy (at fluid temperature of 25°C) |
Frequency pulse | ± 2.5 RS% (100% to 20% of maximum flow rate) ± 0.5 FS% (20% to 5% of maximum flow rate) |
|||
Unit pulse | ± 2.0 RS% (100% to 20% of maximum flow rate) ± 0.4 FS% (20% to 5% of maximum flow rate) |
||||
Piping connection (Screw size) | R1/2 | R1/2 | R1 | ||
Fluid temperature range | 0 to 60℃(Non-freezing) | ||||
Fluid conductivity range | 50 µS/cm or higher | ||||
Target liquids | Conductive liquid that does not corrode the material exposed to it. | ||||
Operating pressure | 1 MPa or less | ||||
Pressure loss | 0.02 MPa or less | ||||
Ambient temperature and humidity | Temperature: -20°C to 60°C Humidity: 35% to 85% RH (Non-condensing) |
||||
Responsiveness | 63% response Damping time: 2 s (Standard) | ||||
Signal cables | Length: 0.5 m, 4-wire Red: Power + line White: Output 1 Blue: Power – line (GND) Yellow: Output 2 |
||||
LED displays | One LED display on the sensor body Green: Indicates flow rate with three scales of blinking speed. Red: Indicates abnormal state with the number of blinks. |
||||
Installation position | Free (Vertical piping is recommended.) | ||||
Output common specifications | NPN open collector Current capacity: 20: mA or less Voltage: 30 VDC or less Residual voltage when ON: 1 V or less |
||||
Output 1*2 | Frequency pulse*1 | Duty ratio | Standard 200 Hz (Can be configured by 0.1 Hz in the range between 20 and 400 Hz.) |
||
Unit pulse | 0.001 L/P (Standard) | 0.01 L/P (Standard) | 0.1 L/P (Standard) | ||
Alarm*3 | Can be selected from normal open (Standard) or normal close. Alarm contents (Power supply and voltage drops/ meter failure/ empty fluid/ excessive flow rate/ excessive flow noise/ reverse flow) |
||||
Switch*4 | Can be selected from normal open (Standard) or normal close. Level judgment value: Can be configured by 1% in the range of 0 – 100%. (The maximum flow rate is converted to 100%.) |
||||
Output 2 *2 | Unit pulse | Same as output 1. | |||
Alarm*3 | Same as output 1. | ||||
Switch*4 | Same as output 1. | ||||
Safety Class | IP X4(IP 64 compatible) | ||||
Current Consumption | 100mA or less | ||||
Power Source | Supply isolated power at 12 -24 VDC (±10%). Use of one unit of power supply is recommended for one unit of VN. |
||||
Exposed materials to fluids | Body: PPS resin Electrodes: SUS 316 L O ring: FKM Grounding ring: SUS 316 |
* 1: The frequency at maximum flow rate
* 2: The set value of Output 1 and 2 and options are the factory-default settings. The set value cannot be changed after installation.
* 3: The alarm can only be selected for either Output 1 or 2.
* 4: The window judgment uses Output 1 and 2.
(Note) Not complied with the lightning surge protection in CE.
Dimensions
(Unit:mm)
Model | VN05 | VN10 | VN20 |
---|---|---|---|
L | 85 | 95 | 110 |
W | 47 | 47 | 49 |
H | 49 | 52 | 62 |
φ D | 5.2 | 10 | 20 |
R | 1/4 | 1/2 | 1 |
Other information
Wiring Diagram
Wiring method of supplied cords
・We recommend the pull-up resistance of open-collector Output 1 and 2 to be 10 to 20K Ω.
・If you use the product out of the recommended range, make sure the sink current (Is) is within 20 mA.
Compatible display unit
Compatible with compact electromagnetic flow sensors VN/VNS
Display Unit ASI-100
The versatile analog output allows you to apply it for a variety of uses such as controlling and recording flow rate.