TRXUltrasonic Flow Meters for Air
(Diameters 40A, 50A, 65A, and 80A)

TRX Photo

Features

A cost effective ultrasonic flow meter specialized for measuring air and nitrogen is now available!

It has realized a wide range of measuring ability and ZERO pressure loss using the characteristics of ultrasonic waves. It is also well-equipped to handle dust and mist and has excellent durability compared with conventional flow meters that use other measuring principles because it does not have moving parts.

The meter can be selected from two types of power sources: built-in batteries that can run 10 years without needing power construction, or an external power supply (24 VDC).

・To understand and visualize the usage of compressed air as a measure of saving electric power..
・To understand the amount of nitrogen refined and used in a factory. (Can be applied to a degreasing treatment.)

Specifications

Model External power specifications TRX40D-C/4P TRX50D-C/4P TRX65D-C/4P TRX80D-C/4P
Built-in battery specifications TRX40-C/4P TRX50-C/4P TRX65-C/4P TRX80-C/4P
Diameter (Nominal diameter) 40A 50A 65A 80A
Power source External power specifications 24 VDC ± 10%; Power consumption: 1.1 W or less
Built-in battery specifications Lithium battery with a battery life of about 10 years (under an environmental temperature of 20°C)
Measurable fluids Air (mainly the air in a factory) or nitrogen
* Please select when ordering.
Fluid temperature and humidity - 10 to 60°C and 90% RH or less
Operating pressure Less than 0 to 1 MPa (Gauge pressure)
Flow rate range (Actual flow) ±1.3~80m3/h ±2.5~150m3/h ±4~240m3/h ±5~300m3/h
Flow measurement accuracy ±2%RS ±8~80m3/h ±15~150m3/h ±24~240m3/h ±30~300m3/h
±5%RS ±1.3~8m3/h ±2.5~15m3/h ±4~24m3/h ±5~30m3/h
Low flow rate cut-off ±0.2m3/h ±0.4m3/h ±0.5m3/h ±0.8m3/h
Normal conversion accuracy ± 2.5% (at 500 kPa and 25°C)
Display
(Switched by buttons)
Model LCD 7 segments (with unit and alarm displays)
Main display *2 [Forward flow display mode]
Accumulated flow rate: 00000000.0 (Nm3/h) in 9 digits
Trip accumulated flow rate: 0000000.0 (Nm3/h) in 8 digits
Instantaneous flow rate: 00000.00 (NL/min) in 7 digits
[Forward and reverse flow display mode]
Forward accumulated flow rate: 00000000.0 (Nm3/h) in 9 digits
Reverse accumulated flow rate: -0000000.0 (Nm3/h) in 8 digits
Instantaneous flow rate: 00000.00 (NL/min) in 7 digits
Sub display Instantaneous flow rate:
000.00 (Nm 3/h, less than 200 Nm3/h) in 5 digits
0000.0 (Nm 3/h, 200 Nm3/h or more and less than 2000 Nm3/h) in 4 and 1/2 digits
00000 (Nm 3/h, 2000 Nm3/h or more) in 5 digits [200 A × 10]
Pressure: 0000.0 kPa in 5 digits
Temperature: 00.0°C in 3 digits
Output Current output 4 to 20 mA (± 0.5% FS); Load resistance: 400 Ω or less; Upper output current: 22 mA
Select output from instantaneous flow rate, pressure, and temperature by pressing a button.
A separate power supply (24 VDC ± 10%) is necessary if you use the meter of the built-in battery specifications. *1
Output range (4 to 20 mA): Instantaneous flow rate
0 to ☐☐☐☐ Nm3/h (Forward flow display mode)
– ☐☐☐☐ to ☐☐☐☐ Nm3/h (Forward and reverse flow display mode)
☐☐☐☐ are the values set by the button.
Pressure: 0 to 1000 kPa
Temperature: -10 to 60°C
Contact output Two Open-drain output systems
Maximum load: 24 VDC, 10 mA
Maximum frequency: 10 Hz
Duty: 35% to 65%
Output 1: Unit pulse (Forward flow)
Output 2: Unit pulse (Reverse flow)
Flow rate upper and lower limits alarm
Selection of telegram output
Pulse output units: 100 NL/P or 1000 NL/P
Connection method Wafers (Fixed by JIS 10 K flanges)
Mounting position Horizontal (LCD display to be placed upward), or vertical mounting
The materials exposed to gases Aluminum alloy, PPS, fluorosilicone rubber, etc.
Mass External power specifications 1.0kg 1.2kg 1.4kg 1.7kg
Built-in battery specifications 1.1kg 1.3kg 1.6kg 1.8kg
Installation location Indoor and outdoor (The safety class IP64 qualified)
Storage temperature -20 to 70°C; No condensing
Regulatory compliance CE marking compliant (EN 61000- 6-2:2005 and EN 61000- 6-4: 2007)

*1: In the actual flow measurement setting, the digits of the accumulated flow rate display, instantaneous flow rate display and pulse output vary.
*2: When displaying the instantaneous flow (NL /min), the main display (accumulated flow rate), sub-display (instantaneous flow rate [Nm3/h]), pressure (kPa) and temperature (°C) will not be displayed.
* Piping conditions:
20D or higher in upstream and 5D or higher in downstream for the 25A/32A models. (When using in the forward and reverse display mode, 20D or higher on both sides.)
10D or higher in upstream and 5D or higher in downstream for the 40A or larger models. (When using in the forward and reverse display mode, 10D or higher on both sides.)
For more information, please contact our sales and branch offices.

Conversion chart between actual and normal flow rates

Conversion conditions 40A 50A 65A 80A
Temperature (°C) Gauge pressure (MPa) Minimum Maximum Minimum Maximum Minimum Maximum Minimum Maximum
Actual flow rate (m3/h) 1.3 80 2.5 150 4 240 5 300
20 0.7(Nm3/h) 9.6 590 18 1100 30 1770 37 2210
30 0.5(Nm3/h) 7.0 430 13 800 21 1280 27 1600
0.7(Nm3/h) 9.3 570 18 1070 29 1710 36 2140
formula

Dimensions

(Unit: mm)

Model W D H Mass
TRX400 76 81 163 1.1 kg (1. Built-in lithium battery model)
1.0 kg (2. External power supply model)
TRX500 90 96 176 1.3 kg (1. Built-in lithium battery model)
1.2 kg (2. External power supply model)
TRX650 108 117 197 1.5 kg (1. Built-in lithium battery model)
1.4 kg (2. External power supply model)
TRX800 117 126 220 1.8 kg (1. Built-in lithium battery model)
1.7 kg (2. External power supply model)