Aichi tokei denki Vietnam, VNS10RE, Cảm biến dòng điện từ VNS10RE, Pitesco là đại lý chính hãng Aichi tokei denki Vietnam

 

Feature

  • ・Compact and excellent cost performance
  • ・Outstanding reliability with no moving parts
  • ・Suitable for use in machines
  • ・Easy-to-check 2-color LED(status) indicator
  • ・2 selectable outputs (Unitpulse,High-density pulse,Warning,Switch)

Examples of use

sample6  

Measurement principle

principle

Specifications

Principal of measurement Electromagnetic type with Faraday’s law of electromagnetic induction
Model (PROVISIONAL) VNS05RE/RF VNS10RE/RF VNS20RE/RF
Accuracy assured flow-rate range *2 0.05~1 L/min 0.5~10 L/min 3.0~60L/min
Measurement starting flow-rate 0.025 L/min 0.25 L/min 1.5 L/min
Piping connection Socket type union joint (16A) Socket type union joint (16A) Socket type union joint (20A)
Accuracy *3 Unit pulse output ±2.0%RS (100~20% of the maximum flow-rate) ±0.4%FS (20~5% of the maximum flow-rate)
Response time (at 63% response) Standard: 2 seconds. Setting within the range of 0.1600 seconds is available.
Fluid temperature range 0~40°C, freezing must be avoided. (VNS05 can resist 15 minutes per day of 95°C, whereas its accuracy is out of guarantee.
Measurable fluid
  • Sodium hypochlorite (Concentration of 1~12%)
  • Sodium hydroxide aqueous solution (Concentration of 10~25%)

For other kind of liquid, by selecting with reference to the following major materials of the fluid-touching materials, please consult with us for suitability confirmation.

Working ambient temperature range -20~60°C
Ambient temperature range for storage -20~70°C
Fluid pressure range 0~1MPa
Signal cable
  • Standard cable length 0.5m
  • 4-wires (AWG26) Line 1: Power + line Line 2: Power – line Line 3: Output 1 Line 4: Output 2
  • Top of the each: Soldered stranded wire
Display 1 LED display at the flowsensor’s body

 

  • Green: Flow-rate indication (Indication with blinking speed of 3 steps)
  • Red: Alarm indication (Indication of abnormality with numbers of blinking)
Place of installation Indoor installation (In case of outdoor installation, please take necessary measure so that the flowsensor is not exposed to rain and sun beam directly.)
Enclosure IPX4
Corresponding standard CE Standard *1
Fluid-touching materials

Main body: PEEK resin

Electrodes: Pure titanium (2 kinds)O-ring: For sodium hypochlorite, etc. – FKM (Fluoro rubber)
※VNS05RF,VNS10RF,VNS20RF

For Sodium hydroxide aqueous solution, etc. — EPDM (Ethylene propylene rubber)
※VNS05RE,VNS10RE,VNS20RE

Installation position Free (Vertical piping is recommended.)